
The WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element ships with these headline parameters: alarm threshold instantaneous alarm on manual activation, contact closure under 100 ms, reset within 2 s using the test key, accuracy class en 54-11 type a indirect operation, single-pole changeover contacts rated 60v dc 1 a, end-of-line supervision on every uplink, response time alarm within 100 ms locally, uplink to the panel or platform within 3 s on 433 mhz and within 12 s on nb-iot, power supply 3.6v er18505m lithium cell, 5-year service life, field-replaceable drawing 9 ua standby, 120 ma peak transmit, 20 ma in alarm, output 433 mhz fsk, lorawan 1.0.3 class a or 4g lte cat-1 uplink per sku, with a supervisory heartbeat every 2 h, coverage one unit per escape route exit, maximum 30 m travel distance to the nearest call point per en 54-11 practice, alarm output local red led plus panel or platform alarm, optional group sounder trigger through the paired gateway, ip42 indoor standard, ip67 with the weatherproof housing and hinged transparent cover for outdoor and marine sites enclosure, -10 deg c to +55 deg c, ip67 sku to -30 deg c operating range and 92 mm x 92 mm x 38 mm, 178 g net including the cell. As of September 20, 2026, Wanlin Group (Shenzhen, China) officially launches its 2026 smoking detection alarm export programme, featuring the WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element as the flagship OEM and ODM component for overseas buyers, cross-border trading companies, hotel and hospital groups, facility managers and regional distributors who are sourcing cigarette smoke and vape detection hardware from a China-based source factory under the Wanlin brand. The new release targets importers, hotel and resort operators, hospital estate teams, school and university housing offices, airport and transit operators, mall and office facility managers, system integrators, insurers, wholesale distributors and public procurement tender bidders who source certified smoking detection equipment directly from a Chinese manufacturer rather than paying the western brand premium of Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor. Wanlin Group as the smoking detection alarm supplier, exporter and original manufacturer now opens its doors to global local partners, regional exclusive distributors, overseas cooperation partners and strategic OEM clients across 60+ destination markets.
Core parameters: WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element, manual activation through a resettable membrane element with a supervised microswitch and a latching alarm state until key reset. Sensing element resettable silicone membrane element over a sealed microswitch, test key reset, no break-glass consumable. Alarm threshold instantaneous alarm on manual activation, contact closure under 100 ms, reset within 2 s using the test key. Accuracy class en 54-11 type a indirect operation, single-pole changeover contacts rated 60v dc 1 a, end-of-line supervision on every uplink. Response time alarm within 100 ms locally, uplink to the panel or platform within 3 s on 433 mhz and within 12 s on nb-iot. Power supply 3.6v er18505m lithium cell, 5-year service life, field-replaceable. Power consumption 9 ua standby, 120 ma peak transmit, 20 ma in alarm. Output signal 433 mhz fsk, lorawan 1.0.3 class a or 4g lte cat-1 uplink per sku, with a supervisory heartbeat every 2 h. Coverage area one unit per escape route exit, maximum 30 m travel distance to the nearest call point per en 54-11 practice. Alarm output local red led plus panel or platform alarm, optional group sounder trigger through the paired gateway. IP rating ip42 indoor standard, ip67 with the weatherproof housing and hinged transparent cover for outdoor and marine sites. Operating temperature -10 deg c to +55 deg c, ip67 sku to -30 deg c. Humidity range 10-95% rh non-condensing. Housing material flame-retardant abs v-0 housing, ip67 sku in polycarbonate with a transparent hinged cover and 316 stainless-steel screws. Dimensions and weight 92 mm x 92 mm x 38 mm, 178 g net including the cell. Certifications EN 54-11 / CE / RoHS / REACH / FCC Part 15 / GB 19880 CCCF. The 2026 smoking detection range is built on WANLIN-365 multi-sensor tobacco and vape aerosol detectors with electrochemical, semiconductor and MEMS channels, WANLIN-303 standalone and WANLIN-307 and WANLIN-309 IoT smoke detectors on 433 MHz, LoRaWAN, NB-IoT, 4G LTE Cat-1 and Wi-Fi, WANLIN-340 rate-of-rise heat detectors in A1R, A2S, BR and CS classes to EN 54-5, WANLIN-222 resettable wireless call points to EN 54-11, WANLIN-656 sounder strobes to EN 54-3 and EN 54-23, WANLIN-860 wireless fire alarm panels to EN 54-2, EN 54-4 and EN 54-21, WANLIN-705 smart electrical fire monitors to GB 14287.2 and GB 14287.3, WANLIN-868D LoRa concentrator gateways with Modbus TCP, MQTT and BACnet IP, WANLIN-770 wireless pressure gauges to EN 837-1, WANLIN-780 wireless level meters to EN 61326, WANLIN-260 Wi-Fi home fire safety kits, WANLIN-710 Wi-Fi smart circuit breakers to GB 16917 and the A119-YW aerosol smoke test gun and heat detector tester for commissioning and periodic inspection rounds, shipped with CE, UKCA, UL, ULC, FCC, CCCF and SASO documentation packages.
Executive summary - 12 buyer-relevant points:
- Flagship model WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element, manual activation through a resettable membrane element with a supervised microswitch and a latching alarm state until key reset
- Sensing element resettable silicone membrane element over a sealed microswitch, test key reset, no break-glass consumable
- Alarm threshold instantaneous alarm on manual activation, contact closure under 100 ms, reset within 2 s using the test key
- Accuracy and response en 54-11 type a indirect operation, single-pole changeover contacts rated 60v dc 1 a, end-of-line supervision on every uplink / alarm within 100 ms locally, uplink to the panel or platform within 3 s on 433 mhz and within 12 s on nb-iot
- Power and consumption 3.6v er18505m lithium cell, 5-year service life, field-replaceable / 9 ua standby, 120 ma peak transmit, 20 ma in alarm
- Output signal 433 mhz fsk, lorawan 1.0.3 class a or 4g lte cat-1 uplink per sku, with a supervisory heartbeat every 2 h
- Coverage and notification one unit per escape route exit, maximum 30 m travel distance to the nearest call point per en 54-11 practice / local red led plus panel or platform alarm, optional group sounder trigger through the paired gateway
- 15 wireless models and test tools from one factory: WANLIN-303 standalone smoke alarm, WANLIN-307 and WANLIN-309 IoT smoke detectors, WANLIN-340 heat detector, WANLIN-222 manual call point, WANLIN-656 sounder strobe, WANLIN-705 electrical fire monitor, WANLIN-860 fire alarm panel, WANLIN-770 pressure gauge, WANLIN-780 level meter, WANLIN-365 gas detector, WANLIN-260 home safety kit, WANLIN-868D gateway, WANLIN-710 smart circuit breaker and the A119-YW detector tester
- MOQ 400 pcs, lead time 18-25 days, EXW / FOB Shenzhen / CFR / CIF / DDP supported, 60 months warranty
- Flagship field reference Transit public toilets, Changi Airport Terminal 3, Singapore: Six toilet blocks on the departure level, each with 14 to 22 cubicles, a shared hand-wash .
- Target buyer: importer, hotel and hospital group, facility manager, school and university housing office, airport and transit operator, system integrator, distributor, cross-border trading company, public tender bidder
- Contact: wanlinfirecontrol@163.com / +8613261677119 / www.wanlinfire.com
This article is written for B2B buyers in Abuja, Nigeria who are enforcing a no-smoking rule in places where a normal fire alarm is the wrong instrument, because the thing that has to be detected is not a fire: it is a low, slow concentration of tobacco or vape aerosol in a bathroom, a guest room, a ward, a stairwell or a washroom, often with the door shut and the ventilation running, and a life-safety smoke alarm calibrated to let people escape a fire will simply ignore it until something is actually burning. Wanlin Group operates its own manufacturing facility in Shenzhen with SMT lines, sensor calibration benches, an aerosol test chamber and a radio laboratory, exporting smoking detection, vape detection, gateway, panel and test equipment to 60+ countries across Europe, North America, the Middle East, Southeast Asia, Africa, Oceania and Latin America under the Wanlin brand. Our WANLIN detection packages are engineered for OEM and ODM partners who need EN 14604 and EN 54 alignment, documented nuisance-alarm control, an anonymised reporting option where privacy is a condition, and stable long-term supply for project contracting, distribution and public tender supply.
No-smoking rules are now written into hotel guest contracts, hospital estate policies, university housing terms, airport operating licences, warehouse insurance conditions and national indoor air legislation, and the enforcement gap is the same everywhere: the rule exists, the building has a fire alarm, and the fire alarm is calibrated to ignore exactly the thing the rule prohibits. A lit cigarette in a closed bathroom produces a particulate concentration that never reaches the threshold of an EN 14604 device, and vape aerosol produces even less. That is the demand curve importers are now buying against - not new-build fire detection but a dedicated enforcement layer that reports an event to the desk, the duty manager or the facilities queue while leaving the certified evacuation chain untouched. Hotel groups, hospital estates, school and university housing offices, transit operators, mall and office facility managers, insurers and public procurement bodies are the buyers, and they are increasingly explicit that a disconnected ceiling alarm in the toilet is not an answer. Contractors, importers and cross-border trading companies supplying Abuja, Nigeria increasingly source smoking detection hardware from China-based original manufacturers like Wanlin rather than buying piecemeal from western distributors, because the total cost of ownership of a Wanlin detection package is 35-55% below european or north american assembled equivalents at the same documented sensitivity, and because one factory covers the sensor, the radio, the gateway, the panel and the test tool on a single shipment.
Market access in Abuja, Nigeria is anchored on SONCAP certification with the Federal Fire Service design approval for public buildings. Smoking detectors, vape and tobacco aerosol sensors, gateways, control panels and test tools shipped into Abuja, Nigeria clear customs on one HS-coded packing list: the radio type-approval reference, the CE and RoHS declarations, the EN 14604 or EN 54 type-test reference and the calibration record travel with the pallet, so the insurer review and the local authority acceptance pass without a second shipment or a re-test at destination, which requires a documented conformity route, a declaration referencing the applicable product standard, a radio type-approval reference for the wireless models and third-party approval body involvement where the scheme demands it. Cross-border buyers are advised to verify the declaration, the type-test report and the approval body reference of every device prior to import, since non-compliant or un-certificated detection devices may be rejected by customs authorities, refused by the insurer, or invalidate the building fire certification.
Reference: EN 14604 smoke alarm devices, EN 54 series for fire detection and fire alarm systems, EN 54-25 radio transmission for fire systems, EN 54-21 remote transmission, ISO 7240, EN 50194 and EN 50291 gas and CO detection practice, NFPA 72 and BS 5839 system design and maintenance practice, FCC and CE radio type-approval for the 433 MHz, LoRaWAN, NB-IoT, LTE and Wi-Fi models, plus local building, privacy and workplace air-quality requirements in the destination market, and Wanlin Group 2026 smoking detection alarm export programme documentation.
The WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element is engineered inside a four-stage smoking detection architecture rather than as a standalone gadget: (1) a sensing stage that resolves the particulate and vapour signature of tobacco and vape aerosol instead of the combustion curve a fire alarm looks for, because the two are not the same signal; (2) a nuisance-rejection stage that separates that signature from shower steam, deodorant spray, hand-dryer heat and cleaning chemicals, which is where most competing products fail in the first month; (3) a supervised wireless transport stage that carries the event to the desk, the BMS or the cloud on 433 MHz, LoRaWAN, NB-IoT, 4G LTE Cat-1 or Wi-Fi depending on who owns the network and who pays the bill; and (4) a response stage where the rule is explicit - an alert to housekeeping, the duty manager, the nurse station or the facilities queue, with the certified evacuation chain either untouched or connected through one supervised contact the local fire officer controls. Because the package is sold as one design, the sensitivity step, the confirmation window, the radio choice and the privacy configuration all come from the same specification instead of four vendors each protecting their own part of the liability.
Three sub-modules define the engineering depth:
The featured model is WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element, part of the Wireless Resettable Manual Call Point (LoRaWAN / 4G / 433 MHz) family, configured as the 433 mhz build (1 variant). FOB Shenzhen reference price is $16.80 per piece at MOQ 400 pcs, with bulk tier pricing ranging $14.62-$18.65 depending on detection class, measuring range, enclosure rating, output protocol variant, certification scope and packaging artwork. Lead time is 18-25 days from PO confirmation and 30% T/T deposit receipt, with 60 months warranty.
The unique technical signature of WANLIN-222 on this variant combination is documented in the table below. Every parameter listed is engineering-verified by our Shenzhen lab and cross-checked against the applicable EN 54, ISO 7240, UL or EN 837-1 product standard, the declaration of conformity scope, the system compatibility statement and the accuracy and response time requirement of the destination market.
| Specification | Value |
|---|---|
| working_principle | Manual activation through a resettable membrane element with a supervised microswitch and a latching alarm state until key reset |
| sensing_element | Resettable silicone membrane element over a sealed microswitch, test key reset, no break-glass consumable |
| alarm_threshold | Instantaneous alarm on manual activation, contact closure under 100 ms, reset within 2 s using the test key |
| accuracy_class | EN 54-11 Type A indirect operation, single-pole changeover contacts rated 60V DC 1 A, end-of-line supervision on every uplink |
| response_time | Alarm within 100 ms locally, uplink to the panel or platform within 3 s on 433 MHz and within 12 s on NB-IoT |
| power_supply | 3.6V ER18505M lithium cell, 5-year service life, field-replaceable |
| power_consumption | 9 uA standby, 120 mA peak transmit, 20 mA in alarm |
| output_signal | 433 MHz FSK, LoRaWAN 1.0.3 Class A or 4G LTE Cat-1 uplink per SKU, with a supervisory heartbeat every 2 h |
| coverage_area | One unit per escape route exit, maximum 30 m travel distance to the nearest call point per EN 54-11 practice |
| alarm_output | Local red LED plus panel or platform alarm, optional group sounder trigger through the paired gateway |
| ip_rating | IP42 indoor standard, IP67 with the weatherproof housing and hinged transparent cover for outdoor and marine sites |
| operating_temp | -10 deg C to +55 deg C, IP67 SKU to -30 deg C |
| humidity_range | 10-95% RH non-condensing |
| housing_material | Flame-retardant ABS V-0 housing, IP67 SKU in polycarbonate with a transparent hinged cover and 316 stainless-steel screws |
| dimensions_weight | 92 mm x 92 mm x 38 mm, 178 g net including the cell |
| certifications | EN 54-11 / CE / RoHS / REACH / FCC Part 15 / GB 19880 CCCF |
Wanlin smoking detection packages are working across six continents: Dubai Marina serviced apartments, Changi airport transit toilets, a Greater Manchester mental health ward, Riyadh mall restrooms, a Berlin student residence, Shinjuku karaoke rooms, La Defense office washrooms, a Sydney CBD tower, Rustenburg mining ablution blocks, Sao Paulo metro restrooms, a Gangnam gaming venue, Kuala Lumpur strata offices, an Amsterdam detention facility, a Toronto residence, a Mumbai private hospital, an Istanbul hotel, a Nairobi UN compound, Mexico City airport, a Makati call centre and a Warsaw logistics warehouse. Below are 5 detailed scenarios drawn from those deployments, each with a site, a device count, a radio and privacy configuration, an installation window and a measured or witnessed outcome rather than a capability claim.
Scenario 1: Transit public toilets, Changi Airport Terminal 3, Singapore. Six toilet blocks on the departure level, each with 14 to 22 cubicles, a shared hand-wash area and a ceiling void that runs the full length of the block, so a single point detector in the void was never going to attribute an event to a cubicle. The facilities team asked for zone-level identification, not cubicle-level, and rejected any camera because of the privacy policy the airport publishes. The installed design is one WANLIN-307 NB-IoT unit per two cubicles mounted on the partition top rail plus one WANLIN-340 thermal unit in the hand-wash area where hand dryers and hot water create the temperature noise the optical channel would misread. Coverage runs on the airport private NB-IoT network, so there is no SIM card and no per-device monthly fee, and the events land in the existing facilities help-desk queue. Installation was done in 04:00-06:00 windows across nine nights with no block closure, and the measured nuisance rate over the first six months was 0.3 calls per device per year, most of them traced to a single block where a cleaning contractor switched to a steam mop.
Scenario 2: Mental health inpatient ward, Greater Manchester, United Kingdom. A 22-bed psychiatric ward where smoking is prohibited inside but patients smoke in the bathroom, and where the two real risks are a fire started on bedding by an unattended cigarette and the oxygen-enriched atmosphere in the two treatment rooms. The trust fire officer refused any device with a strobe because of the photosensitive patient group, and refused any device that a patient could remove with a coin. The answer was a tamper-proof WANLIN-222 call point at the nurse station for manual confirmation plus WANLIN-365 semiconductor units in the bathrooms reporting on LoRaWAN to the ward office, with the WANLIN-860 panel mapped so that a bathroom event pages the nurse directly instead of triggering the building evacuation. The units were mounted at 2.4 m with security screws and a 3 mm mesh guard. Commissioning took four days including the false-alarm walkthrough with the cleaning and clinical teams, and the first year of operation recorded 71 real events against 4 nuisance activations, which the trust audit accepted as an improvement on the previous arrangement of staff doing 15-minute bathroom rounds.
Scenario 3: Mall restrooms and family lounges, Riyadh, Saudi Arabia. A three-level shopping centre with 34 restroom clusters, family rooms on every level and prayer rooms where the management suspected smoking after hours. The operating constraint here is procurement, not engineering: SABER requires a product certificate of conformity per SKU and a shipment certificate per consignment, and the mall operator will not accept hardware that cannot be registered. Wanlin supplied the two SABER PCoC registrations before the order was placed and the SCoC with the packing list. Technically the design puts one WANLIN-309 Wi-Fi unit per restroom cluster - the mall already had full Wi-Fi coverage and did not want to add a radio network - with the WANLIN-868D gateway used only to bridge the clusters onto the BMS over Modbus TCP so that the facilities dashboard shows smoking events next to the HVAC and washroom-cleaning tickets. Installation took 16 nights with a three-man team working after closing. Across the first three months the mall logged 214 events, of which 188 occurred after 22:00 in the two ground-floor restrooms nearest the food court, and cleaning was rescheduled around that pattern rather than spread evenly.
Scenario 4: Student residence bathrooms, Berlin, Germany. A 640-room student residence run by a housing association where the problem was not fire but damage: eight bathroom ceilings had been replaced in two years after smoking, and the association insurer had begun asking about detection. There is no building management system, no budget for cabling, and the residents union objected to anything that looked like surveillance. The accepted scheme is a battery WANLIN-303 unit per bathroom on the association own 433 MHz group, with a local sounder limited to 65 dB so it reads as a reminder rather than a fire alarm, plus an anonymous monthly count per floor published on the notice board. No camera, no microphone, no per-room identity, which is what made the union accept it. Two caretakers installed 640 units in 12 working days using adhesive mounts so the concrete ceilings were not drilled. Ceiling replacements in the following year fell from eight to one, and the association has since written the same specification into its refurbishment standard for the other four residences it manages.
Scenario 5: Karaoke box rooms, Shinjuku, Tokyo, Japan. A 32-room karaoke chain where every room is a sealed box with heavy acoustic treatment, a curtain across the doorway and an extract grille that pulls air out faster than a ceiling detector can accumulate smoke. The owner had already tried conventional smoke detectors and disconnected them after the second month because cigarette smoke in a karaoke room is continuous, not an event, and every session ended in a building alarm. The redesign accepts that fact: WANLIN-FD900 units are not used here because the owner will not install a camera in a room guests pay for by the hour, so the installed layer is WANLIN-365 multi-sensor units calibrated to the particulate profile of tobacco aerosol rather than to a fire curve, reporting on LoRaWAN to the front desk with a 90-second confirmation window before anything sounds. staff response is a knock on the door and a written warning, and the evacuation chain is untouched. The chain installed the first site in five days, then rolled the other 11 sites over three months, and the recorded outcome was a stop to the false building evacuations plus a cleaning-cost reduction of roughly 18% per room because rooms are no longer deep-cleaned after every session.
The WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element and the wider Wanlin smoking detection package deliver 10 distinct advantages for cross-border B2B buyers who source no-smoking enforcement hardware directly from a Chinese manufacturer:
Combined, these advantages allow Wanlin partners to win hotel group rollouts, hospital estate programmes, school and university housing projects, airport and transit contracts, mall and office facilities packages, warehouse insurance remediation, public procurement tenders and national distributor frameworks, secure regional distribution rights and serve end customers under their own brand at 35-55% lower landed cost compared to legacy western distribution channels.
The WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element carries the following certifications as standard scope: EN 54-11 / CE / RoHS / REACH / FCC Part 15 / GB 19880 CCCF. Optional add-on documentation available on request includes VdS (Germany), LPCB (United Kingdom), ETL and FM (global insurance), UL and ULC (North America), ActivFire (Australia), CNBOP-PIB (Poland), TZUS (Czech), ATEX and IECEx for hazardous-area devices, KC (Korea), NOM (Mexico), SASO and SABER (Saudi Arabia), and radio type-approval reports per destination for the 433 MHz, LoRaWAN, NB-IoT, LTE and Wi-Fi models. All devices are produced in an ISO 9001:2015 and ISO 14001:2015 certified factory with RoHS and REACH declarations issued per batch.
Cross-border buyers should note that smoking detection compliance sits on four legs: the alarm device standard such as EN 14604 or the applicable EN 54 part, the radio type-approval for the wireless models in the destination band plan, the system design and maintenance rule such as NFPA 72, BS 5839 or AS 1670 where the device is documented as part of a building system, and the destination conformity route plus environmental declarations. Wanlin supplies a pre-validated compliance pack per model covering DoC templates, type-test references, radio approvals, calibration records and the annual survey template, which typically moves importer approval from a quoted 8-14 weeks down to 2-4 weeks for most markets. Where privacy law applies, Wanlin also supplies the anonymised reporting configuration and the wording pack. What stays local is the installation licence, the acceptance by your authority and any civil work - Wanlin does not contract abroad and does not present itself as a licensed installer in your city.
For a typical first-time buyer ordering 4000 pieces of WANLIN-222 Wireless Manual Call Point with Resettable Non-Break Element, the economics stack is:
| Cost Layer | USD per piece | USD for 4000 pcs |
|---|---|---|
| FOB Shenzhen factory price | $16.80 | $67,200.00 |
| + Sea freight FCL 40HQ (estimated) | $3.02 | $12,080.00 |
| CIF destination port | $19.82 | $79,280.00 |
| + Customs duty 3-10% (region dependent) | $1.18 | $4,720.00 |
| + Local delivery + warehousing | $6.30 | $25,200.00 |
| DDP landed cost | $27.30 | $109,200.00 |
Sample order cost is USD 120 per SKU refundable against the first bulk order above MOQ. 30% T/T deposit and 70% balance against B/L copy is the standard payment term. L/C at sight is accepted for orders above USD 80,000. Production lead time is 18-25 days. Warranty is 60 months. Free DOA replacement within 60 days of receipt.
Below are 8 frequently asked questions from overseas buyers, cross-border trading companies and regional distributors sourcing smoking detection and vape alarm hardware from China. Each answer is anchored on Wanlin actual commercial terms, certification scope and field experience across 60+ export markets under the Wanlin brand.
Answer: A life-safety smoke alarm to EN 14604 is calibrated to detect a developing fire so that occupants can leave, and it is deliberately insensitive enough that cooking and steam do not empty a building. A smoking detection device is calibrated for the opposite job: it has to see a low, slow concentration of tobacco or vape aerosol in a room where nothing is burning, and it has to do it while ignoring shower steam, deodorant spray and cleaning chemicals. In practice that means a different sensing channel, a different threshold and a different alarm behaviour - an alert to the desk or the duty manager, not a building evacuation. Wanlin supplies both layers and keeps them separate: the WANLIN-303 platform carries the EN 14604 and EN 54 referencing documentation for the life-safety function, while the WANLIN-365 and WANLIN-307 platforms carry the tobacco and vape aerosol detection function. Buyers who try to use one device for both jobs usually end up either with nuisance alarms or with no detection at all, which is why we ask about the intended response before quoting.
Answer: They can, and pretending otherwise is how a rollout fails in the first month. Wanlin manages it four ways: the multi-sensor channel on WANLIN-365 distinguishes the particulate and vapour signature of tobacco aerosol from the water droplet profile of steam; sensitivity is field-adjustable in steps so a humid bathroom can be set one step down; the confirmation window is configurable, typically 30 to 120 seconds, so a transient plume does not raise an event; and the WANLIN-705 platform logs the false-alarm history so thresholds can be tuned on real data rather than guessed. In the Dubai Marina apartment deployment the sensitivity was dropped one step before handover specifically because of shower steam, and the measured nuisance rate across a Changi deployment was 0.3 calls per device per year, with most traced to a cleaning contractor switching to a steam mop. We would rather discuss the nuisance sources at design stage than claim zero false alarms.
Answer: The optical and multi-sensor platforms do not record identity, audio or video; they report a concentration event with a time and a zone. The only Wanlin product that carries a camera is the WANLIN-FD900 flame detection platform, and we actively advise against it in rooms where privacy is the concern - we declined it in the Tokyo karaoke project and in the Toronto residence for exactly that reason. For deployments where a privacy position has to be published, Wanlin supplies an anonymised reporting configuration: aggregate counts per floor or per building per hour, no per-room identity. That configuration is what allowed the Berlin housing association residents union, the Amsterdam works council and the Toronto university counsel to accept the installation, and we will supply the wording we have used before as a starting point for your own review.
Answer: Typical response to a lit cigarette in a closed bathroom is 20 to 60 seconds depending on room volume and ventilation; response to vape aerosol is slower because the particulate mass is lower, and vape deployments are normally set with a longer confirmation window. Sensitivity is adjustable in discrete steps on the WANLIN-365 and WANLIN-307 platforms, and the confirmation window is set in the panel or the gateway configuration, so a hotel bathroom, a hospital corridor and a warehouse loading bay can each be tuned differently on the same hardware. For reference, the WANLIN-303 platform reports response in seconds to the documented fire curve, the WANLIN-365 in seconds against the tobacco particulate profile, and every shipped unit carries its own calibration record in the specification block that accompanies the article and the datasheet.
Answer: It depends on who owns the network and who pays the bill. If the site has no IT support and no appetite for a monthly fee, the 433 MHz group with a WANLIN-860 panel is usually right and it is what the Berlin housing association and the Istanbul hotel chose. If the building already runs a LoRaWAN network for plant or door telemetry, joining it is usually free and is what the Rustenburg mine, the Mumbai hospital and the Warsaw warehouse did. If there is no network and no Wi-Fi but there is cellular coverage and a willingness to pay a small annual fee, NB-IoT or 4G LTE Cat-1 is the answer. If the building already has reliable Wi-Fi and the IT department will allow the devices on it, WANLIN-309 is the cheapest to deploy and is what the Riyadh mall and the Makati call centre used. Wanlin ships all four radio options on the same mechanical platform, so the choice can be made per building rather than per project.
Answer: Every shipment carries the CE and RoHS and REACH declarations, the FCC declaration for radio models, the EN 14604 or EN 54 referencing statement as applicable to the SKU, the type-test reference, the calibration record and a multi-language manual. On request we supply UL and ETL documentation for North America, UKCA for Great Britain, SASO SABER PCoC per SKU and SCoC per shipment for Saudi Arabia, ECAS for the UAE, BIS for India, SIRIM for Malaysia, TISI for Thailand, SNI for Indonesia, DTI-BPS for the Philippines, NOM for Mexico, INMETRO for Brazil, KC for Korea, SABS for South Africa and CCCF for China. What stays with your company is the installation licence, the acceptance by your local authority and any civil work. Wanlin does not hold a contracting licence abroad and does not present itself as a licensed installer in your city, and we say so in writing because it is the question that comes back at audit.
Answer: MOQ is 200 pieces per detector SKU for the standard housing and 500 pieces for private-label artwork; mixed containers are accepted and most first orders are one project kit rather than a single SKU. Lead time is 10-18 days for in-stock configurations from PO and deposit, 25-35 days for custom artwork, custom threshold profiles or non-standard housings. Warranty is 60 months on detector and sensor families, 36 months on control and gateway families, with DOA replacement inside 60 days. OEM covers your brand on the housing and carton, your manual and insert, your name as importer of record on the documentation with Wanlin as manufacturer, and a custom default threshold profile if your market needs one. Sample orders are charged at cost and refunded against the first bulk order above MOQ.
Answer: There are four routes. Project supply is for contractors buying against their own jobs, priced per project with the documentation pack included. Authorised reseller carries territorial protection and list pricing with a co-marketing contribution. Regional exclusive distribution starts after a first-year volume commitment and adds joint certification cost-sharing and a protected country. Strategic OEM is where the product carries your brand and your documentation cover, with a dedicated engineering contact and an 18-month price lock. All partners receive firmware updates for the life of the product, DOA replacement inside 60 days, a named account manager with a four-business-hour response target, destination-language manuals, and one joint booth per year at Intersec Dubai, Security Essen, Secutech, Firex International or Canton Fair on a cost-share basis. Wanlin is recruiting global local partners now and will happily start with a single pilot building before anyone commits to a container.
Wanlin smoking detection packages have shipped to 60+ markets across 6 continents, with the United Arab Emirates, Saudi Arabia, Singapore, the United Kingdom, Germany, Japan, Australia, South Africa, Brazil, South Korea, Malaysia, the Netherlands, Canada, India, Turkey, Kenya, Mexico, the Philippines and Poland among the most active sourcing routes. Below are 4 anonymised project references drawn from 2024-2026 installations. Each record states what the earlier scheme was, what was actually installed, and what was measured or witnessed, rather than restating a capability claim.
Case 1: Facilities contractor wins a national retail chain contract on documentation, Poland. A facilities management company bidding for a 140-store retail chain maintenance contract lost the first round on price and was told the second round would be scored on the smoking and air-quality section of the tender. The contractor came to Wanlin for a package it could price per store. The answer was a fixed kit: four WANLIN-309 units per store on the existing Wi-Fi, one WANLIN-868D gateway per 20 stores presenting Modbus TCP into the contractor help-desk platform, and a Polish-language manual set. The part that won the tender was the documentation folder - CE and RoHS declarations, the EN 14604 and EN 54 referencing statements, the annual inspection template and the incident report form - because the retailer had been unable to get any of it from the incumbent supplier. The contractor won the contract, rolled 140 stores in 11 weeks, and has since extended the same kit to two smaller chains it already maintained.
Case 2: School district replaces a punitive scheme with an anonymous count, New Zealand. A secondary school district had installed cheap battery smoke alarms in the toilets, watched them be removed, and escalated to a disciplinary scheme that the student council publicly objected to. The board wanted something that protected the building without treating students as suspects. Wanlin supplied WANLIN-303 units in tamper-resistant housings reporting to a WANLIN-860 panel at the administration office, configured to give an anonymous daily count per block and no audible alarm in the toilet itself, plus a WANLIN-340 unit in each changing room where vapour was the nuisance risk. The district published the privacy position to parents before installation, which took nine days across four schools. Vandalism of the devices, which had been the whole problem under the previous scheme, dropped to two incidents in the first year, and the board credits the published privacy stance rather than the hardware.
Case 3: Distributor builds a private-label line for the hospitality channel, Spain. A Madrid-based distributor selling cleaning and hygiene products to hotels wanted a smoking detection line under its own brand, because its customers were already asking and it did not want to send them to a competing wholesaler. Wanlin ran the OEM route: the distributor artwork on the housing and the carton, its manual and its insert, the WANLIN-303 and WANLIN-365 platforms unchanged underneath, MOQ 500 units per SKU on the first order and 300 thereafter. The documentation was issued with the distributor name as the importer of record and Wanlin as the manufacturer, which is what the Spanish market expects. The first container shipped 11 weeks after the artwork was signed off. The distributor has since added the bathroom unit to its standing catalogue and reorders roughly every six months, and the line now accounts for a double-digit share of its technical category, which it had not expected.
Case 4: Hospital estate solves an oxygen-area problem without touching the fire system, India. A hospital group with five sites was told by its insurer that smoking near oxygen manifold rooms had to be addressed as a condition of renewal, and its fire consultant refused to let any new device connect to the certified fire alarm panel because the panel was at the end of its supported life and any modification would trigger a re-certification. The accepted design separates the systems entirely: WANLIN-365 units in the manifold rooms and lounges, WANLIN-340 thermal units in corridors, all on LoRaWAN into a WANLIN-868D gateway that feeds the hospital own monitoring dashboard, with a single supervised relay held open unless maintenance enables it. BIS referencing documentation was included in each site file. Five sites were completed in 14 weeks. The insurer accepted the arrangement at renewal, and the group has since used the same separation argument for its oxygen-line monitoring project, which had been blocked for the same reason.
Wanlin offers 3 partnership tiers for cross-border smoking detection buyers, hotel and hospital groups, facility contractors and overseas cooperation partners:
| Tier | Annual Volume | Discount | Exclusivity | Support |
|---|---|---|---|---|
| Authorized Reseller | USD 30,000+ | 0% (list price) | No | Standard 60-month detector warranty |
| Regional Distributor | USD 100,000+ | 22% off list | Single country | Co-marketing USD 6,000/year, joint certification cost-share |
| Strategic OEM Partner | USD 320,000+ | 32% off list | Multi-country | Dedicated engineering team, joint roadmap, 18-month price lock |
All partners receive: free firmware updates for life of product, free DOA replacement within 60 days, dedicated account manager and WhatsApp response within 4 business hours, free certification documentation and test report copies, destination-language manual support, anonymised reporting configuration where privacy law requires it, and one joint trade-show booth per year at Intersec Dubai, Security Essen, NFPA Conference, Firex International, Secutech, SICUR, FeuerTrutz, FireExpo or Canton Fair on a cost-share basis.
Wanlin Group 2026 smoking detection alarm export program is now open for global B2B buyers, regional distributors, hotel and hospital groups, facility management contractors, cross-border trading companies and OEM and ODM partners across 60+ destination markets. To initiate a sourcing discussion, request a quotation or schedule a factory audit in Shenzhen, please contact our export team via the channels below. Sample orders ship within 3-7 days via DHL Express for in-stock SKUs; custom-configuration samples require 7-15 days. Standard lead time for bulk OEM orders is 18-25 days. Strategic OEM Partner applications are reviewed quarterly and require a minimum USD 320,000 annual commitment.
We sincerely invite global fire and safety equipment buyers, national importers, hotel and hospital estate teams, facility management companies, school and university housing offices, transit operators, system integrators and cross-border trading companies to engage in long-term cooperation with Wanlin Group as your China-based OEM and ODM partner, regional exclusive distributor or strategic global supplier under the Wanlin brand. Wanlin is the Chinese source factory behind 60+ country detection projects, the SMT lines, aerosol calibration chamber and radio laboratory behind every batch, and this 12-section export program. Let us build safer buildings together.
Article signature:
working_principle: Manual activation through a resettable membrane element with a supervised microswitch and a latching alarm state until key reset sensing_element: Resettable silicone membrane element over a sealed microswitch, test key reset, no break-glass consumable alarm_threshold: Instantaneous alarm on manual activation, contact closure under 100 ms, reset within 2 s using the test key accuracy_class: EN 54-11 Type A indirect operation, single-pole changeover contacts rated 60V DC 1 A, end-of-line supervision on every uplink response_time: Alarm within 100 ms locally, uplink to the panel or platform within 3 s on 433 MHz and within 12 s on NB-IoT power_supply: 3.6V ER18505M lithium cell, 5-year service life, field-replaceable power_consumption: 9 uA standby, 120 mA peak transmit, 20 mA in alarm output_signal: 433 MHz FSK, LoRaWAN 1.0.3 Class A or 4G LTE Cat-1 uplink per SKU, with a supervisory heartbeat every 2 h coverage_area: One unit per escape route exit, maximum 30 m travel distance to the nearest call point per EN 54-11 practice alarm_output: Local red LED plus panel or platform alarm, optional group sounder trigger through the paired gateway ip_rating: IP42 indoor standard, IP67 with the weatherproof housing and hinged transparent cover for outdoor and marine sites operating_temp: -10 deg C to +55 deg C, IP67 SKU to -30 deg C humidity_range: 10-95% RH non-condensing housing_material: Flame-retardant ABS V-0 housing, IP67 SKU in polycarbonate with a transparent hinged cover and 316 stainless-steel screws dimensions_weight: 92 mm x 92 mm x 38 mm, 178 g net including the cell certifications: EN 54-11 / CE / RoHS / REACH / FCC Part 15 / GB 19880 CCCF